種別 |
論文 |
主題 |
Influence of Joint Position on Shear Behavior of Segmental Concrete Beams with External Tendons |
副題 |
|
筆頭著者 |
Dinh Hung NGUYEN(Tokyo Institute of Technology) |
連名者1 |
二羽淳一郎(東京工業大学) |
連名者2 |
Chunyakom SIVALEEPUNTH(Tokyo Institute of Technology) |
連名者3 |
長谷川剛(ドーピー建設工業) |
連名者4 |
|
連名者5〜 |
|
キーワード |
接合位置、プレストレストコンクリート、セグメントコンクリートはり、外ケーブル、せん断挙動、joint position、prestressed concrete、segmental concrete beam、external tendon、shear response |
巻 |
30 |
号 |
3 |
先頭ページ |
565 |
末尾ページ |
570 |
年度 |
2008 |
要旨 |
This paper presents a study on the structural behavior of segmental concrete beams with external prestressing, focusing on the response of the beams under shear considering the joint position in the shear span. Three segmental concrete beams prestressed with external tendons and with different positions of the segmental joint in shear span have been tested to investigate the shear failure mechanisms. The experimental results with emphasis on the effects of epoxied joint position have shown the difference in the shear failure mechanism. |
PDFファイル名 |
030-01-3095.pdf |