| 種別 | 論文 |
| 主題 | ESTABLISHMENT OF TEST METHOD THAT CAN COMPARE ADHESIVE STRENGTH BETWEEN PLASTER MORTAR AND CONCRETE AT THE LABORATORY LEVEL |
| 副題 | |
| 筆頭著者 | Peiyi ZHANG(Hiroshima University) |
| 連名者1 | 寺本篤史(広島大学) |
| 連名者2 | 大久保孝昭(広島大学) |
| 連名者3 | 近藤諒太(広島大学) |
| 連名者4 | |
| 連名者5 | |
| キーワード | accelerated degradation、adhesive unity、interfacial stress、plastering mortar、thermal cycle |
| 巻 | 42 |
| 号 | 1 |
| 先頭ページ | 563 |
| 末尾ページ | 568 |
| 年度 | 2020 |
| 要旨 | This study proposed the new experimental method that can evaluate the durability of adhesive strength between plaster mortar and concrete substrate at the laboratory level. In this method, a cyclic thermal load is applied on a part of the plaster mortar surface as a means to accelerate degradation. The experimental results show that the adhesive strength of the loaded part decreases significantly. In addition, the deformation and interfacial stress of the mortar/substrate adhesion system under this thermal cycling load conditions were calculated by finite element analysis. |
| PDFファイル名 | 042-01-1093.pdf |