EFFECTIVE LENGTH OF CATHODIC PROTECTION EMBEDDED STEEL WITH SACRIFICIAL ANODE UNDER NON-HOMOGENEOUS CHLORIDE ENVIRONMENT |
副題 |
|
筆頭著者 |
Rahmita Sari RAFDINAL(Kyushu University工学府建設システム工学専攻) |
連名者1 |
M田秀則(九州大学Faculty of Engineering) |
連名者2 |
佐川康貴(九州大学Faculty of Engineering) |
連名者3 |
山本大介(九州大学Faculty of Engineering) |
連名者4 |
|
連名者5 |
|
キーワード |
cathodic protection、effective length、embedded steel、sacrificial anode |
巻 |
37 |
号 |
1 |
先頭ページ |
955 |
末尾ページ |
960 |
年度 |
2015 |
要旨 |
This study was carried out to identify the effective length of embedded segmented steel element with sacrificial anode exposed to non-homogeneous chloride environment against macro-cell corrosion. Four concrete specimens which consist of chloride contaminated and non-chloride contaminated concrete were evaluated. Results show that sacrificial anode can protect embedded steel in the boundary of non-homogeneous chloride environment with the effective length is about 120 mm until 200 mm from edge of the boundary. |