| 種別 | 論文 |
| 主題 | EFFECTIVE LENGTH OF CATHODIC PROTECTION EMBEDDED STEEL WITH SACRIFICIAL ANODE UNDER NON-HOMOGENEOUS CHLORIDE ENVIRONMENT |
| 副題 | |
| 筆頭著者 | Rahmita Sari RAFDINAL(Kyushu University工学府建設システム工学専攻) |
| 連名者1 | M田秀則(九州大学Faculty of Engineering) |
| 連名者2 | 佐川康貴(九州大学Faculty of Engineering) |
| 連名者3 | 山本大介(九州大学Faculty of Engineering) |
| 連名者4 | |
| 連名者5 | |
| キーワード | cathodic protection、effective length、embedded steel、sacrificial anode |
| 巻 | 37 |
| 号 | 1 |
| 先頭ページ | 955 |
| 末尾ページ | 960 |
| 年度 | 2015 |
| 要旨 | This study was carried out to identify the effective length of embedded segmented steel element with sacrificial anode exposed to non-homogeneous chloride environment against macro-cell corrosion. Four concrete specimens which consist of chloride contaminated and non-chloride contaminated concrete were evaluated. Results show that sacrificial anode can protect embedded steel in the boundary of non-homogeneous chloride environment with the effective length is about 120 mm until 200 mm from edge of the boundary. |
| PDFファイル名 | 037-01-1154.pdf |