EFFECTIVENESS OF STEEL SURFACE CONDITIONS ON CATHODIC PROTECTION BY SACRIFICIAL ANODE IN CONCRETE |
副題 |
|
筆頭著者 |
Rahmita Sari RAFDINAL(Kyushu University) |
連名者1 |
M田秀則(九州大学) |
連名者2 |
佐川康貴(九州大学) |
連名者3 |
山本大介(九州大学) |
連名者4 |
|
連名者5 |
|
キーワード |
Sacrificial anode in concrete、cathodic protection、rusted steel、potential、depolarization、犠牲陽極、電気防食、発錆した鉄筋、電位、復極量 |
巻 |
38 |
号 |
1 |
先頭ページ |
1197 |
末尾ページ |
1202 |
年度 |
2016 |
要旨 |
The purpose of this study was carried out to observe the effectiveness of initial condition (rusted or non-rusted) of embedded steel in partially-repaired concrete on sacrificial anode cathodic protection systems. Three concrete specimens consisting of "chloride-contaminated existing concrete" and "chloride-free repair sections" were prepared. Environmental change during exposure time was also included as an experimental parameter. Results show that placing non-rusted steel bars in repair concrete sections is the desirable as initial condition when CP (Cathodic Protection) is applied and exposed to both dry and humid conditions. |